Electrical Specifications: (23℃±5℃)
Programmed Voltage and Current: (5 minutes after power on)
| Range | Resolution | Accuracy | Comments |
Voltage V (C.V.) | 0 – 40V | 1mV | 0.05% ± 9mV | Typical ± 5mV |
Current A (C.C.) | 0 – 5A | 1mA | 0.2% ± 9mA | Typical ± 5mA |
C.V.: Constant Voltage, C.C.: Constant Current
Voltage/Current Read Back Accuracy:
| Range | Resolution | Accuracy |
Voltage V (C.V.) | 0.1 – 40V | 1mV | 0.1% ± 12mV |
Current A (C.C.) | 0.05 – 5A | 1mA | 0.2% ± 12mA |
C.V.: Constant Voltage, C.C.: Constant Current
General Specifications:
Load Regulation: | 1mV/A |
Line Regulation: | No effect if line voltage falls within 90V to 130V for 115V nominal, 200V to 240V for 230V nominal. |
Fixed 5V / 2A Accuracy: | 5V ±0.25V |
Fixed 3.3V / 3A Accuracy: | 3.3V ±0.16V |
| When 5V or 3.3V output is less than 1V (shorted), the corresponding symbol will be shown in LCD to warn the users. |
Ripple and Noise (0 ~ 40V, 0 ~ 5A): | < 3mVrms (C.V.), typical 1mVrms |
Ripple and Noise (0 ~ 40V, 0 ~ 5A): | < 3mArms (C.C.), typical 1mArms |
Ripple and Noise (5V/2A, 3.3V/3A): | 10mVrms ~ 20mVrms, 10mArms ~20mArms |
Temperature Coefficient: | < 100ppm/℃ |
OCP detection: | Current A > 0.05A |
C.V. or C.C. Detect and Display: | Current > 0.05A |
Power Source: | 115V (90V to 130V) or 230V (200V to 240V) |
Accessories: | Power cord x 1 Users manual x 1 Testing leads (alligator clips) x 1 set Testing leads (double-side banana heads) x 1 set USB cable x 1 CD (USB driver) x 1 |
Dimensions: | 310mm x 250mm x 133 mm 12.2” x 9.8” x 5.2” |
Weight: | 3.8kg (8.4lbs) |